Measurement #1 Initial Settings
Monitor Profiling Process #1
On this step, you can select probe, set the color patch size and position, select monitor's miscellaneous settings. Next step is here.
①Showing input signal format
It is showing the signal format currently inputting to IS-mini
②Selection of the probe
You can select the probe you are going to use form the combobox. "Emulation without probe" selection is to run demonstration mode with no real probe to confirm how it works for the monitor profile measurement process.
③Setting of Color Patch Size and Position
You can set the size and position of the color patch to measure monitor profile.When you changed the parameter, please click "Update Color Patch" button to update the output of the color patch. Offset X = 0 means center, negative is left, positive is right. Offset Y = 0 means cense and negative is upper and positive is lower.
④Miscellaneous settings of monitor
You can limit the white point code value same or under 1019.
If you are using OLED, color calculation method can be set to Judd Offset method.
⑤The sound when measurement finished
Automatic measurement process takes time so you can play sound when the measurement finished.